A SNP array can help you review the selected DNA positions on its chip. When your question goes beyond that fixed list, whole-genome sequencing (WGS) gives you a broader place to start. Whole-exome sequencing (WES) focuses on the protein-coding parts of genes. The right starting point depends on the position and type of change you want to inspect. [1][2]

Coverage comes before interpretation. Seeing no result does not tell you that a position was tested and matched the reference sequence. A missing call is not a tested reference call. [3][4]

Compare what each file can show

Review questionSNP arrayWGSWES
Which parts of DNA are examined?Selected positions defined by the chip. [1]DNA across the genome, including coding and non-coding regions. [2]Mainly the protein-coding regions targeted by the assay. [2]
Where does it help?Reviewing known markers on the chip, especially common variants. [1][5]Looking beyond a fixed marker list; sequencing pipelines can call single-letter changes and small insertions or deletions. [2][6]Reviewing coding changes in regions that were successfully captured and called. [2][6]
What can be missed?Changes outside the tested positions and uncertain calls at tested markers. [1][3]Calls can be missing or filtered out. Larger rearrangements require an appropriate analysis pipeline. [4][6]Changes outside the target regions, along with missing or filtered calls inside them. [2][4]
What does an empty result mean?The marker may be untested, or it may have no confident call. [1][3]A variant-only file cannot prove a reference call at a position it leaves out. [4]The position may fall outside the assay or remain unresolved in the file. [2][4]

For details on each data type, see the SNP array overview and the WGS and WES overview.

A reference call and a no-call mean different things

A genotype is the DNA call at a position. With a reference call, the called DNA matches the reference sequence there. A no-call means the process did not assign a genotype. An absent position gives you even less information: you need the file's reporting rules and coverage details to understand the omission. [3][4]

The notation depends on the file. For example, 23andMe uses -- for an uncalled marker in downloaded data. That symbol does not mean the marker matched the reference. This is a notation example, not a guide to a particular provider's file. [3]

In a VCF (Variant Call Format) file, the genotype field is labeled GT. For a diploid call, 0/0 means both called alleles match the reference, while ./. means both alleles are missing. These are synthetic notation examples, not a person's DNA data. Even an explicit reference call needs a quality check before you rely on it. [4]

A variant-only VCF can leave out positions where no variant was reported. A gVCF can include information about non-variant regions and reference confidence. Before treating an omitted row as evidence, ask the data provider what the file contains. This explains how the formats work; it does not mean Gene Inspector Pro accepts every gVCF. [4]

Match the technology to the question

For a known common marker, an array can provide useful information if that exact marker is on the chip and has a reliable call. Finding a different marker in the same gene does not establish the result at the position you want to check. [1][5]

Sequencing offers a wider scope when you want to look outside a chip's selected positions. WES can suit a question about a coding region that the assay covers. When you need to look outside coding regions too, WGS is the broader option. Neither name guarantees a usable call at every position. [2][4]

A sequencing file also depends on the software that produced it. A pipeline built for single-letter changes and small insertions or deletions is not a complete analysis of larger DNA rearrangements. Ask which variant classes were analyzed and which were exported. Do not assume a WGS upload includes every kind of variant. [6]

Rare calls from an array deserve extra care. A BMJ study comparing SNP chips with sequencing found that the chips performed well for common variants, but poorly for very rare variants in the datasets studied. That finding does not provide an accuracy estimate for your file. It is a reason to check an unexpected rare call before drawing a conclusion. [5]

Check quality at the position you need

With an array, ask whether the marker was included and whether it received a call. The provider's no-call notation matters more than the size of the downloaded file. With sequencing, ask for the coverage and filtering details for the position you need. A long list of reported variants cannot answer that question on its own. [1][3][4]

A VCF file may include GQ for genotype quality, DP for read depth, AD for the read counts supporting each allele, and FILTER for site-level filters. Each field answers a different question, and they may be absent. Check the file header for their definitions. A passed site filter does not replace genotype-quality information for the sample. [4]

Use allele frequency and MAF to see how common a variant is in a reference population. Frequency and confidence in the DNA call are separate questions. A rare entry deserves careful review, though rarity alone does not prove that the entry is correct or harmful. [5][7]

How Gene Inspector Pro reads each data type

Gene Inspector Pro supports raw SNP array data and WGS/WES data. According to its help documentation, it labels array-detected variants with a minor allele frequency below 0.0001 as Low Quality. That label is a product review flag. It does not establish that a call is false, and an unflagged result still needs appropriate review. [7]

With a supported sequencing file, start with the calls available in that file. On a gene page, you can review the uploaded DNA calls, variant details, and available source records. The guide to reading the Gene page walks through this workflow. The same principle holds for arrays: the software cannot turn a selected-marker file into a sequenced genome. [1][7][8]

Gene Inspector Pro provides information for review and education. It does not diagnose disease or replace a clinical test. If a finding raises a clinical question, discuss it with a qualified healthcare professional before acting on it. [8]

Before you interpret a result

  • Confirm the data type and the exact position you want to review.
  • Check that the position was tested and has a usable call.
  • Distinguish between a reference call, a no-call, and an omitted position.
  • For sequencing, check the coverage, quality fields, filters, and variant classes included in the export.
  • Keep uncertainty about the DNA call separate from uncertainty about what it means.

Sources

  1. NHGRI: DNA microarray technology
  2. MedlinePlus Genetics: whole-exome and whole-genome sequencing
  3. 23andMe: what “not determined” means
  4. VCF specification and GATK: genomic variant call format
  5. Weedon and colleagues, BMJ: SNP chips and rare variants
  6. GATK: short variant discovery and structural variant discovery
  7. Gene Inspector Pro help: limitations of SNP arrays and allele frequency and MAF
  8. Gene Inspector Pro: how to read the Gene page and medical disclaimer